The thermal relay plays a vital role in protecting electrical equipment such as motors. Correct application of it can effectively prevent overloads, ensure the stable operation of equipment, and extend the service life of the equipment.


I. Key Points for Selection
Matching of Rated Current: Select the rated current value of the thermal relay according to the rated current of the equipment to be protected. Generally speaking, the rated current of the thermal relay should be slightly larger than that of the equipment. For example, for a motor with a rated current of 10A, a thermal relay with a rated current of 11 - 12A can be selected to ensure that it will not malfunction during normal operation and can respond in a timely manner in case of an overload.
Consideration of Thermal Element Characteristics: Different thermal elements have different heating characteristics and operating time characteristics. For equipment with frequent starts and large inertia, it is necessary to choose thermal elements with appropriate time-delay characteristics to avoid the impact of the starting current of the equipment and prevent false tripping. For example, for the motor of a crane, whose starting current is large and the starting time is long at the moment of starting, special thermal elements are needed to adapt to this working condition.


II. Precautions for Installation
Location Selection: It should be installed near the equipment to be protected so that it can accurately sense the temperature changes of the equipment. Meanwhile, it should avoid being installed in environments with high temperature, high humidity or strong electromagnetic interference to prevent affecting its normal operation. For example, do not install the thermal relay directly opposite the heat dissipation vent of the motor to avoid false operation due to being directly blown by hot air; nor should it be installed near strong magnetic field sources such as large transformers.
Connection Method: The connecting wires between the thermal relay and the equipment should have an appropriate cross-sectional area to ensure reliable connection and low resistance. If the wires are too thin, the connection points will heat up, affecting the accuracy of the operation of the thermal relay; if the wires are too thick, it will cause a waste of resources and inconvenience in installation. Usually, the wire specifications are selected according to the rated current of the thermal relay and the current-carrying capacity standard of the wires. For example, for a thermal relay with a rated current of 16A, a copper wire with a cross-sectional area of 2.5 square millimeters can be selected.


III. Debugging and Setting
Setting of Operating Current: Set the operating current of the thermal relay according to the actual operation situation and load characteristics of the equipment. Generally, it is initially set according to the rated current of the equipment, and then during the trial operation of the equipment, the operation of the thermal relay is observed and adjusted appropriately. For example, for an equipment whose actual operating current is slightly lower than the rated current, the operating current can be set to 1.05 - 1.1 times of the rated current to improve the protection sensitivity while avoiding false operation.
Selection of Reset Mode: There are two reset modes for thermal relays: manual reset and automatic reset. Manual reset is suitable for occasions where manual confirmation is required to restart the equipment after the fault is eliminated, which can enhance safety; automatic reset is suitable for equipment with high requirements for continuous production and that can automatically resume operation after the fault is eliminated. For example, for the motor protection on an automated assembly line, if the fault can be quickly eliminated and it is hoped that the motor can quickly restart automatically, the automatic reset mode can be selected.


IV. Q&A Session
(I) Question: Can the thermal relay protect against short-circuit faults?
Answer: The thermal relay is mainly used for overload protection. For short-circuit faults, its response speed is slow and it cannot effectively protect. Short-circuit faults usually require short-circuit protection devices such as fuses or circuit breakers to quickly cut off the circuit.
(II) Question: What should be done if the thermal relay malfunctions frequently?
Answer: First, check whether the selection is improper, such as whether the rated current is too small or the characteristics of the thermal element are not suitable. Second, check whether there are abnormal factors such as high temperature, vibration or electromagnetic interference in the installation environment, and make adjustments or replace the appropriate thermal relay according to specific problems.


V. Application Process Steps
(I) Decision-making for Selection
Determine the parameters such as the rated current, starting characteristics and operating environment of the equipment to be protected.
Screen out suitable models in the thermal relay product catalog according to these parameters, focusing on whether the rated current and the characteristics of the thermal element match.
(II) Installation and Deployment
Select a suitable installation location to ensure that the surrounding environment meets the requirements and there is no high temperature, high humidity or strong electromagnetic interference.
Use wires of appropriate specifications to correctly connect the thermal relay to the equipment to be protected. The connection should be firm to ensure good contact.
(III) Debugging and Operation
Initially set the operating current of the thermal relay according to the rated current of the equipment.
Start the equipment for trial operation, observe the operation of the thermal relay, fine-tune the operating current according to the actual situation, and determine the reset mode at the same time.


VI. Summary
The thermal relay plays an irreplaceable role in the field of electrical equipment protection. By following the requirements for selection, installation precautions, debugging and setting, combined with the methods for dealing with faults in the Q&A session and the standardized application process steps, it can be ensured that the thermal relay can accurately and effectively play the role of overload protection in various electrical equipment, reduce the risk of equipment damage due to overloads, improve the reliability and stability of the electrical system, and ensure the smooth progress of production activities.

Relevant News
One Hole Offset Floating Tongue Lug

AWG mechanical connectors are a crucial part of electrical connections. Proper maintenance can extend their lifespan, ensure the stability of the electrical system, ...

More
AWG Terminal & Connectors

In the electrical world, although AWG Terminal & Connectors are small, they are of vital importance. They accurately construct circuit connections, ensure the smooth...

More

GET A QUOTE

GET IN TOUCH NOW
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All